Controller Alarm Guide

HOME

Search Results Found 1000 Cases.

0001

Alarm Contents

TH ERROR

A TH error was detected during reading from an input device. The read code that caused the TH error and how many statements it is from the block can be verified in the diagnostics screen.

0002

Alarm Contents

TV ERROR

An error was detected during the single–block TV error. The TV check can be suppressed by setting bit 0 (TVC) of parameter No. 0000 to “0”.

0003

Alarm Contents

TOO MANY DIGIT

Data entered with more digits than permitted in the NC instruction word. The number of permissible digits varies according to the function and the word.

0004

Alarm Contents

INVALID BREAK POINT OF WORDS

NC word(s) address + numerical value not in word format. This alarm is also generated when a custom macro does not contain a reserved word, or does not conform to the syntax.

0005

Alarm Contents

NO DATA AFTER ADDRESS

NC word(s) address + numerical value not in word format. This alarm is also generated when a custom macro does not contain a reserved word, or does not conform to the syntax.

0006

Alarm Contents

ILLEGAL USE OF MINUS SIGN

A minus sign (–) was specified at an NC instruction word or system variable where no minus signal may be specified.

0007

Alarm Contents

ILLEGAL USE OF DECIMAL POINT

A decimal point (.) was specified at an address where no decimal point may be specified, or two decimal points were specified.

0009

Alarm Contents

IMPROPER NC-ADDRESS

An illegal address was specified, or parameter 1020 is not set.

0010

Alarm Contents

IMPROPER G-CODE

An unusable G code is specified.

0011

Alarm Contents

FEED ZERO ( COMMAND )

1) The cutting feedrate instructed by an F code has been set to 0. 2) This alarm is also generated if the F code instructed for the S code is set extremely small in a rigid tapping instruction as the tool cannot cut at the programmed lead.